%@LANGUAGE="VBSCRIPT" CODEPAGE="1252"%>
|
![]() |
||||||||||||||
|
ARS-3(15MB)
Reflective, Protective or Architectural Color Coating System for Modified Bitumen Roofs APPLICATION GUIDE
1. DESCRIPTION
The Acrymax ARS-3(15MB) Coating System is an elastomeric coating
system specified as a reflective coating system for energy savings,
a protective coating system, or as a color coating for architectural
or aesthetic purposes. This coating system utilizes Acrymax AF-130MB a state-of-the-art
elastomeric acrylic coating designed specifically for modified bitumen
roofs. AF-130MB offers superior adhesion to new modified bitumen membranes
and other asphaltic substrates. The ARS-3(15MB) system provides a
monolithic roof covering with superior weatherability and durability and offers protection for modified
bitumen roofs from UV and normal weathering degradation. Acrymax Coatings are waterborne materials that
are VOC compliant and exceed all regulatory requirements. The ARS-3(15MB)
System when applied properly will yield a minimum final membrane thickness
of 12 mils and an average membrane thickness of 15 mils. 2. MATERIAL The material
used in the ARS-3(15MB) System is Acrymax AF-130MB. 3. APPLICATION EQUIPMENT
Acrymax AF-130MB can be applied by brush, roller, or spray.
Airless spray is the most efficient method of application where proper
conditions and expertise exist. Suggested spray equipment should be
capable of 2500 – 3000 psi with output of 2 - 2.5 gallons per minute.
Tip size .027 to .041. Application
by roller or brush may require additional coats to achieve uniform
membrane thickness, but material requirements will generally remain
the same. Rollers should be medium or long nap. (3/4” recommended) 4. INSTALLATION Installation of the ARS-3(15MB) System is accomplished in three
(3) basic steps: (a) Preparation,
(a) Preparation Acrymax AF-130MB coating must have
a clean surface to adhere to. Proper surface preparation is the key
to successful applications. All dirt, debris, oils etc. must be removed
by the most effective method possible. High-pressure water (2000 psi
minimum) is the preferred method. Vacuuming, stiff brooming, and low-pressure
water washing can also be used. When high-pressure water washing is
used it should be done at a pressure suitable to remove embedded dirt
and contaminants without damaging the substrate that is being cleaned
and care must also be taken to make sure that water A tape test should be used to determine
acceptability of cleaned surface for coating application. This is done by applying masking tape
to the surface to be coated, and then peeling off the tape. If the
adhesive side of the tape shows contaminants that will interfere with
the adhesion of the coatings, then further cleaning or use of a primer
may be necessary. (b) Application of AF-130MB
Before application of coatings verify
that the surface to be coated is cleaned and prepared properly. At
any time during application of the Acrymax coatings if roof surface
becomes contaminated with dirt, dust or other materials that will
interfere with adhesion of the coatings then cleaning measures must
be taken to restore the surface to a suitable condition. Dust should
be blown off of surfaces to be coated with compressed air or blowers
before application of coatings. All required materials must be applied
and minimum dry film thickness achieved.
1.
Apply 1st
coat of Acrymax AF-130MB in a color that will contrast with the finish
coat. Apply in a uniform manner at minimum
application rate of 1 gallon per 100 square feet.
2.
Allow to dry a minimum
of 2 to 4 hours before applying finish coat.
3.
Apply 2nd
coat of Acrymax AF-130MB in the desired finish color. Apply in a uniform
manner at minimum
application rate of 1 gallon per 100 square feet. (c) Inspection Inspect entire roof area and touch-up deficient areas with
additional Acrymax AF-130MB as necessary to insure complete and uniform
coverage. 5. LIMITATIONS These are general guidelines for application
of the Acrymax ARS-3(15MB) System. The material requirements may vary
depending on the specific job requirements. If unusual conditions exist, contact Acrymax
Technical Service at 610-566-7470. Acrymax Fluid Applied Elastomeric
roofing systems must be applied to structurally sound substrates and
properly prepared surfaces. All surfaces must be clean 6. WARRANTY Acrymax offers limited material warranties
for the ARS-3(15MB) System when all materials are used in strict accordance
with all of Acrymax’s written requirements and recommendations and
required dry film thicknesses are achieved. Acrymax’s sole responsibility
under this limited material warranty is for defective material and
Acrymax’s obligation shall not exceed the purchase price of the Acrymax
materials used or part thereof proven to be defective. Submittal of
required documentation is required for warranty. Consult Acrymax for
details. This warranty gives specific legal rights and
you may have other legal rights that vary from state to state. No
statement by anyone may supersede this limited material warranty,
except when done in writing by Acrymax’s Technical Service Office
in Notes:
1.
Acrymax coatings
are waterborne. Consequently application of these materials must not
be done when rain or other conditions such as fog or dew are possible
before coating can dry
2.
Surfaces must always
be clean before application of AF-130MB Coatings. Care must be taken
to insure that on-site manufacturing emissions or extended time intervals
after original cleaning do not interfere with any stage of the coating
applications. If either condition occurs then cleaning may
be required again.
3.
Adequate coating
thickness is essential to performance. If the applicator is unfamiliar
in gauging application rates, we suggest that a controllable area
be measured and the specified material be applied. In all cases all
minimum specified material must be applied and proper minimum dry
film thicknesses must be achieved. Care must be taken to insure that
all areas completed including all flashings, roof penetrations, etc.
are coated sufficiently to insure a watertight seal.
4.
Consult ACRYMAX TECHNOLOGIES
if any deviations from published specifications are considered. Unapproved
deviations from application guidelines and specified material requirements
may seriously affect the coating system performance, and shall be
undertaken at the specifier’s, applicator’s or building owner’s own
risk.
5.
Applicator must comply
with all applicable local, state, and federal regulations if lead
based paint or other hazardous materials are encountered.
6.
Roofing is hazardous
work and coatings are very slippery when wet. Comply with fall protection
rules and regulations. Acrymax® is a registered trademark of Acrymax Technologies, Inc. 221 Brooke Street Media, PA 19063
© Copyright 2006 Acrymax Technologies, Inc. |
|||||||||||||||